alarm fire!
In all the houses were built, the switch / socket range of LeGrand. With proper installation in accordance with DIN VDE 0100 - 410:2007 screw colloquially, the assembly with the housing "Kaiser screws" there are no complaints with this company. All outlets have been placed in a hollow wall boxes are very likely also correctly fasten with the housing and mounted so objectionable free. For the sockets used in the concrete walls, the following applies: If these are secured with screws later emperors used the assembly was done with the "claws". This fastening claws break or put in too much of the electrical assembly with a screwdriver.
concerned sockets are held only by the cover, holding the inserting of a DIN Schuko plug, also the cover screw no more, the power strip is pushed backwards and the 4.8 mm plug pin dipped far enough into the spring contact of the socket chassis, touches it only .
This creates a high Contact resistance on the performance drops and heat is generated, especially here in devices with high power radiant heater as irons or the like, at this point then start a fire!
Inrechtweisend: in 28C have been developed all switches sockets for wallpapering brush, 5 broken sockets found two were replaced by property developers, and two more were here in the Abbildung.Eine more unnoticed for the damage to a plasterboard wall (Hohlwandosen mounting with imperial screws) installed again . Connection of a leg iron station burned to the DIN - plug into the power strip to this error. Question of guilt in this case is clearly not the developers, because the sockets before installation must be subjected to a visual inspection and in this case should have been noticed.
following best practices for experienced DIY (at your own risk): If, when inserting a plug of the connector to spring slightly or move the plug after insertion slightly again from the socket. Use the following steps: Turn off the circuit (fuse out) remove the cover, Confirm the outer metal ring of the socket, here are two of the screws is that as far as complaint-free, they are now taking the handle of your screwdriver contact with DIN and GS sign up 1000V and press lightly with the handle should face the center of the outlet center of this Give in this exchange is essential! Is better but you hire a certified electrician or the property developer.